Sign In | Join Free | My china-telecommunications.com
China Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. logo
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd. an exclusive current transformer, split core current transformer, current clamp & voltage transformer manufacturer.
Active Member

8 Years

Home > Ammeter Recorder >

ABS PC Housing Wireless Current Transducer Primary Amp Recorder Meter 25mm Jaw

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Contact Now

ABS PC Housing Wireless Current Transducer Primary Amp Recorder Meter 25mm Jaw

  • 1
  • 2

Brand Name : GFUVE

Model Number : GF2015

Certification : CE, ISO9001

Place of Origin : BEIJING CHINA

MOQ : 1SET

Price : Negotiable

Payment Terms : T/T, Western Union, MoneyGram

Supply Ability : 1000SET/MONTH

Delivery Time : 3days

Packaging Details : Standard Export Box

Name : Ammeter Recorder

Application : 69kV,35kV,20KV, 10kV, 6kV

Color : Gray

Communication : RF433

Measurement Rnage : 1 to 100A, 1 to 300A, 1 to 600A, 1 to 1000A, 1 to 2000A

Accuracy Class : ±1% of reading plus 2 counts

Recording Interval : 1S-3600S

Jaw : 25mm

Basic parameters  Recording ammeter kit 3 wireless current sensors (GF2015A, GF2015B, GF2015C) 433 H : 18x9.5x4.62

Weight : 0.58KG

Contact Now

Ammeter Recorder WIRELESS PRIMARY CURRENT RECORDER METER For Mid Voltage

FEATURES

  • The Primary current recorder uses the same sensor technology as the original Rogowski Coil. The True RMS inductive sensor does not use magnetic materials. The opening of the sensor is electronically closed and external currents are electronically rejected.
  • The accuracy, external current reject, and range of currents measured by the patented amp sensor substantially exceed the performance of the best clamp-on sensors. The key feature of the unit is the ability to leave it deployed on the line to record readings every 15 minutes for 90+ days. It easily attaches to the line with a standard insulating bar. Once on the line, it immediate begins to collect and record the primary current on the line.
  • The Primary current recorder is equipped with a 433M wireless port for communicating the recorded data into the user’s PC. The data is downloaded through GF2015S PC-Link Software, which allows the user to download, view and query the data stored on the Primary current recorder.
  • The housing of the Primary current recorder is made of ABS+PC and is built to operate safely, even in severe utility environments. It is resistant to shock, repels water and is unsusceptible to flame. It also operates within a wide temperature range. The Primary current recorder has the screw insulation bar of installation, which allows it to hang on the line securely in all weather conditions.
  • PC-Link Software is a user-friendly software interface that allows the user to download, view, graph and export data from the Primary current recorder into Microsoft Excel. The data directly transfers from the Primary current recorder into Excel through a 433M Port.

AMP RECORDER

  • Collect and analyze load profiles
  • Easily clamps to the line in seconds
  • Check for load balance
  • Patented open CT sensor with ±1% accuracy
  • 433M communication with no annoying cables to connect
  • Recorded data quickly downloads into the user's PC
  • PC-Link Software interface downloads directly into Microsoft Excel
  • Generate reports and create graphs for profile analysis

PARAMETERS

Basic parameters 
Recording ammeter kit 3 wireless current sensors (GF2015A, GF2015B, GF2015C)
433 HHT(handheld terminal) or 433M wireless data reader(GF2015R)
PC-LinkSoftware software(GF2015S)
Carrying case
Data recording interval 5min, 10min,15min, 30min;
Interval user settable from 1-60min
Communication distance(wireless) 100m
Communication 433M, 868M or 915M (option)
Installation Installation with electricity; Disassemble with electricity
Battery 3.6 volt lithium battery,19000mAh; Battery can be replaced
Software requirements PC-Linksoftware & microsoft Excel
Processor 100 MHz or higher ( 200 MHz or higher recommended)
RAM 32 MB, 64M recommended
Drive space 15 MB to load software, 10 MB of operating Space
Use of position Outdoor or indoor
Electrical parameters 
Range of operation 
Voltage 69kV,35kV,20KV, 10kV, 6kV
Current 1 to 100A, 1 to 300A, 1 to 600A, 1 to 1000A, 1 to 2000A
Sensor opening Up to 2.5 cm
Resolution 
1 to 99.9A 0.1A
100 to 2000A 1A
Amps accuracy ±1% of reading plus 2 counts
Frequency 60Hz (57-63 Hz) or 50Hz (47-53 Hz) models available
Mechanical parameters 
Dimensions (W×D×H) (cm) 18x9.5x4.62
Weight (kg) 0.58
Environmental conditions 
Operating temp. -40°C to 60°C

ABS PC Housing Wireless Current Transducer Primary Amp Recorder Meter 25mm Jaw


Product Tags:

wireless current sensor

      

wireless current transducer

      
Quality ABS PC Housing Wireless Current Transducer Primary Amp Recorder Meter 25mm Jaw for sale

ABS PC Housing Wireless Current Transducer Primary Amp Recorder Meter 25mm Jaw Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)